IviumStat.XRe

Scan range: ±2A/±50V

 FRA/EIS: 10µHz to 8MHz

Wide application range: 

The IviumStat.XRe is well suited for applications requiring a wide dynamic range, such as battery testing, corrosion measurements and electrochemical research applications. It has a power of ±2A and low current ranges down to 1pA full scale, as well as a ±50V compliance voltage.

Complete solution: 

The IviumStat.XRe offers a complete package, all the standard Electrochemical techniques are included. The IviumStat.XRe also has an integrated  high-performance Frequency Response Analyser for EIS measurements from 10µHz to 8MHz. All measurement and dataprocessing software is included (for Windows based PCs).

Safety:

The maximum current or potential of the instrument can be defined by the operator. Thus valuable samples may be protected, and unsafe situations prevented.

Automation: 

Multiple analog and digital input & output ports are available for monitoring & control of peripheral equipment. This functionality is fully integrated in the software.

Expandability:

The IviumStat.XRe can be expanded with a wide variety of options and modules, including a Bipotentiostat, True Linear Scan generator, various power boosters and multiplexers.

IviumStat2.hIviumStat.XRe
System performance
Current compliance±5A±2A
Maximum compliance voltage±10V±50V
Maximum applied voltage±10V below 1A, and ±8V up to 5A±50V
Potentiostat
Applied potential range±10V, 0.02mV res. (20bit)±10V/±50V with 0.02mV/0.1mV res. (20bit)
Applied potential accuracy0.2% or 1mV0.2% or 1mV
Current ranges±1pA to ±10A±1pA to ±10A
Galvanostat
Applied current accuracy0.2%0.2%
Galvanostatic current ranges±10pA to ±10A±100pA to ±10A
Impedance Analyser
Frequency range10µHz to 8MHz10µHz to 8MHz
Environment
Power requirements100-240V, 47-63Hz, 150VA100-240V, 45-63Hz, 300VA
InterfacingUSBUSB
Size (w x d x h)26 x 33 x 12cm26 x 33 x 12cm
Weight4.2kg5.3kg
PC requirementsWindows 8/10/11,
with free USB port
Windows 8/10/11,
with free USB port
  • Automatic current range selection: 1pA to 10A/1mV to 10V (50V)
  • Automatic variable noise filter and potentiostat/galvanostat stability settings
  • Simultaneous acquisition of current/potential and up to 8 peripheral analog signals
  • Real time data display up to 500 pnts/s. Acquisition up to 100,000 pnts/s is stored in instrument memory
  • Applicable scanrates: 1µV/s to 10,000 V/s
  • Minimum interval time: 10µs (0.125µs resolution)
  • Result optimisation by automated tuned filters, gain amplifiers and dc-subtraction

The IviumStat.XRe is controlled via Ivium’s own IviumSoft. This versatile, yet intuitive software, allows instrument control, data management and analysis, peripheral instrument control, etc. IviumSoft can also interface with and be controlled from LabVIEWTM, C++, Delphi, etc. A full suite of IviumSoft is included as standard with each instrument.