Wide application range:
The IviumStat2.h is well suited for applications requiring a wide dynamic range, such as battery testing, corrosion measurements and electrochemical research applications. It has a high power of ±5A and low current ranges, down to 1pA full scale.
Complete solution:
The IviumStat2.h offers a complete package, all the standard electrochemical techniques are included. The IviumStat2.h also has an integrated high-performance Frequency Response Analyser for EIS measurements from 10µHz to 8MHz. All measurement and dataprocessing software is included (for Windows based PCs).
Safety:
The maximum current or potential of the instrument can be defined by the operator. Thus valuable samples may be protected, and unsafe situations prevented.
Automation:
Multiple analog and digital inputs & outputs are available on the peripheral port for monitoring & control of peripheral equipment. This functionality is fully integrated in the software.
Expandability:
The IviumStat2.h can be expanded with a wide variety of options and modules, including a Bipotentiostat, True Linear Scan generator, various power boosters and multiplexers.
| IviumStat2.h | IviumStat.XRe | | |
| | | | |
System performance | | | | |
Current compliance | ±5A | ±2A | | |
Maximum compliance voltage | ±10V | ±50V | | |
Maximum applied voltage | ±10V below 1A, and ±8V up to 5A | ±50V | | |
| | | | |
Potentiostat | | | | |
Applied potential range | ±10V, 0.02mV res. (20bit) | ±10V/±50V with 0.02mV/0.1mV res. (20bit) | | |
Applied potential accuracy | 0.2% or 1mV | 0.2% or 1mV | | |
Current ranges | ±1pA to ±10A | ±1pA to ±10A | | |
| | | | |
Galvanostat | | | | |
Applied current accuracy | 0.2% | 0.2% | | |
Galvanostatic current ranges | ±10pA to ±10A | ±100pA to ±10A | | |
| | | | |
Impedance Analyser | | | | |
Frequency range | 10µHz to 8MHz | 10µHz to 8MHz | | |
| | | | |
Environment | | | | |
Power requirements | 100-240V, 47-63Hz, 150VA | 100-240V, 45-63Hz, 300VA | | |
Interfacing | USB | USB | | |
Size (w x d x h) | 26 x 33 x 12cm | 26 x 33 x 12cm | | |
Weight | 4.2kg | 5.3kg | | |
PC requirements | Windows 8/10/11,
with free USB port | Windows 8/10/11,
with free USB port | | |
- Automatic current range selection: 1pA to 10A/1mV to 10V
- Automatic variable noise filter and potentiostat/galvanostat stability settings
- Simultaneous acquisition of current/potential and peripheral analog signals
- Real time data display up to 3,000 pnts/s. Acquisition up to 2,000,000 pnts/s (1,000,000 stored in instrument memory)
- Applicable scanrates: 1µV/s to 10,000V/s
- Minimum interval time: 0.5µs (0.125µs resolution)
- Result optimisation by automated tuned filters, gain amplifiers and DC-subtraction
- User selectable floating operation
The IviumStat2.h is controlled via Ivium’s own IviumSoft. This versatile, yet intuitive software, allows instrument control, data management and analysis, peripheral instrument control, etc. IviumSoft can also interface with and be controlled from LabVIEWTM, C++, Delphi, etc. A full suite of IviumSoft is included as standard with each instrument.