Çalışma Saatleri : 09:00 - 18:00

XP

XP40 (±40A/±10V), XP20 (±20A/±20V), and XP10 (±10A/±40V)

 Applied voltage range on all instruments is ±10V

 Optional FRA/EIS: 10µHz to 500kHz

 Integrated current interrupt

 Direct K-type thermocouple input connector

Wide application range: 

The XP range of instruments are well suited for applications requiring a high current compliance such as battery research, electrolysis, and fuel cell applications. The range includes the XP40 (±40A/±10V), the XP20 (±20A/±20V), and the XP10 (±10A/±40V). The applied voltage of each instrument is ±10V.

Complete solution: 

The XP instrument offers a complete package, all the standard electrochemical techniques are included. The XP potentiostat also has an integrated  high-performance Frequency Response Analyser for EIS measurements from 10µHz to 500kHz. All measurement and dataprocessing software is included (for Windows based PCs).

Safety:

The maximum current or potential of the instrument can be defined in the software by the operator. Thus valuable samples may be protected, and unsafe situations prevented.

Automation: 

Multiple analog and digital input & output ports are available for monitoring & control of peripheral equipment. This functionality is fully integrated in the software.

XP10XP20XP40
System performance
Current compliance±10A±20A±40A
Maximum compliance voltage±40V±20V±10V
Maximum applied voltage±10V±10V±10V
Potentiostat
Applied potential range±10V, 0.08mV res.±10V, 0.08mV res.±10V, 0.08mV res.
Applied potential accuracy0.2%, or 2mV0.2%, or 2mV0.2%, or 2mV
Current ranges±100pA to ±10A±100pA to ±10A±100pA to ±10A
Galvanostat
Applied current accuracy0.2%0.2%0.2%
Galvanostatic current ranges±10nA to ±10A±10nA to ±10A±10nA to ±10A
Impedance Analyser
Frequency range10µHz to 500kHz10µHz to 500kHz10µHz to 500kHz
Environment
Power requirements100-240V, 45-65Hz, 20VA100-240V, 45-65Hz, 20VA100-240V, 45-65Hz, 20VA
InterfacingUSBUSBUSB
Size (w x d x h)45 x 37 x 10cm45 x 37 x 10cm45 x 37 x 10cm
Weight16kg16kg16kg
PC requirementsWindows 8/10/11,
with free USB port
Windows 8/10/11,
with free USB port
Windows 8/10/11,
with free USB port
  • Automatic current range selection: 100pA to 10A/1mV to 20V
  • Automatic variable noise filter and potentiostat/galvanostat stability settings
  • Simultaneous acquisition of current/potential
  • Full colour  graphics display with real time data
  • Applicable scanrates: 1µV/s to 10,000V/s
  • Minimum interval time: 3.33µs (0.125µs resolution)
  • Result optimisation by automated tuned filters, gain amplifiers and DC-subtraction

The XP instrument is controlled via Ivium’s own IviumSoft. This versatile, yet intuitive software, allows instrument control, data management and analysis, peripheral instrument control, etc. IviumSoft can also interface with and be controlled from LabVIEWTM, C++, Delphi, etc. A full suite of IviumSoft is included as standard with each instrument.